High power 100mw 120mw 150mw 275nm UVC LED chip
1. Features
◆ Package size 6.5*6.5*1.5mm ◆ Use ceramic substrate package
◆ Soldering method: reflow soldering ◆ RoHS compliant
◆ Adopt high-reliability packaging and stable energy ◆Using eutectic technology
Item | Mark | Current(mA) | Min value | Typical value | Max value | Unit |
Forward Voltage | VF | IF=600mA | 13 | 15 | 17 | V |
Forward Current | IF | - | - | 600 | 700 | mA |
Irradication | IV | - | - | 100 | 150 | mW |
Beam angle | 2θ½ | IF=600mA | - | 130 | - | ° |
Wavelength | λp | IF=600mA | 270 | 275 | 285 | nm |
Semi wavelength | △λ | IF=600mA | - | 9.6 | - | nm |
Thermal Ristance | R | IF=600mA | - | 25 | - | ℃/W |
2. Application range
◆ Water/air/surface sterilization, used in various household appliances such as disinfection cabinets and microwave ovens
◆ Clean water sterilization, food and surface sterilization, etc.
3.High power 100mw 120mw 150mw 275nm UVC LED chip Size & Package
Attention of 100mw 120mw 150mw 275nm UVC LED diode chip usage :
(1) Storage:
● To avoid the influence of moisture, we recommend that the product be stored at 5-30°C and the relative humidity is less than 60% before opening the package;
● The unpacked LED light source should be used and installed within 24 hours. If the product is not used up, please dehumidify and vacuum it before storing. When opening for more than one week or the humidity card changes, please be sure to dehumidify. Dehumidification conditions: 60°C±5°C, 12H;
● The product is sealed and stored for one year.
(2) Precautions for assembly:
● Soldering conditions: This product must use reflow soldering. The maximum temperature of the reflow curve should not exceed 260°C. During operation or storage, no external force above 1000g or sharp objects should act on the surface of the lamp beads (such as pressure, friction, etc.) And tools such as pliers and tweezers) to avoid component damage;
● If the operating conditions are exceeded, we will not be able to guarantee the stability of the product. If you need to use the operating conditions beyond, be sure to conduct a risk assessment.
(3) Anti-static measures:
● Please take adequate measures to prevent static electricity generation, such as wearing static rings or anti-static finger cots; products (factories, equipment, machines, carrier waves, and transportation units) in each manufacturing process should be connected to the ground to avoid electrical charging of products.